Sign in →

Interleukin 2 Receptor, Soluble

Additional Codes

Orderable Codes:

Epic Code Atlas Code Mayo Test ID Order LOINC
LAB15347 LAB15347 FIL2S 76039-7

Result Component(s):

Reporting Name Epic Code Atlas Code Mayo Test ID Result LOINC
IL 2 Receptor, Soluble 12301013887 12301013887 FIL2S 76039-7

 

Reporting Name

IL 2 Receptor, Soluble

Specimen Type

Varies


Specimen Required


Specimen Type: Serum

Container/Tube: Red

Specimen Volume: 1 mL

 

 

Serum:

Collection Instructions: Draw blood in a plain red-top tube(s), serum gel tube is acceptable. Spin down within 2 hours of collection and freeze immediately. Send 1 mL of serum frozen in a plastic vial.

 

Separate specimens must be submitted when multiple test are ordered.

Note: Cytokine levels may demonstrate diurnal variation. For longitudinal comparison, it is recommended that cytokine levels be determined at the same time of day.

 




Specimen Minimum Volume

0.4 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Frozen 365 days

Reject Due To

Hemolysis NA
Lipemia NA
Icterus NA
Other Contaminated or Heat-inactivated

Reference Values

175.3 pg/mL - 858.2 pg/mL   

Day(s) Performed

Monday, Wednesday, Friday

Report Available

1 to 6 days

Performing Laboratory

ARUP Laboratories

CPT Code Information

83520

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FIL2S IL 2 Receptor, Soluble 76039-7

 

Result ID Test Result Name Result LOINC Value
FIL2S IL 2 Receptor, Soluble 76039-7

Test Classification

This test was developed and its performance characteristics determined by ARUP Laboratories.

NY State Approved

Yes

Method Name

Quantitative Multiplex Bead Assay