Test Code LAB17561 RETICULOCYTE BATTERY
Additional Codes
Epic Code | Atlas Code | Mayo Access ID | Order LOINC |
LAB17561 | LAB17561 | FAH6073 | in process |
Result Component(s)
Reporting Name | Epic Code | Atlas Code | Mayo Access ID | LOINC |
Reticulocyte Count | 12301000146 | RET | FAH197 | 17849-1 |
Reticulocyte Hemoglobin | 12301018801 | 12301018801 | FAH6074 | 71694-4 |
Immature Reticulocyte Fraction | 12301018802 | 12301018802 | FAH6075 | 33516-6 |
Specimen Information
Container | Specimen | Temperature | Collect Vol | Submit Vol | Min Vol | Stability |
Lavender Top (EDTA) | Whole Blood | Refrigerate | 2.5 mL | 2.5 mL | 0.5 mL | 48 hrs |
*Lavender Microtainer | 0.6 mL | 48 hrs |
Invert tube gently 10 times.
*While a microtainer is an optional tube type in rare circumstances, it is not recommended.
Ambient temperature is acceptable - specimen is stable for 24 hrs.
Test Schedule / Analytical Time / Test Priority
Daily / 24 hours / Available STAT
Method
Automated Cell Counter
CPT(s)
Description | CPT Code |
Reticulocyte Battery | 85046 |
Instrumentation
Sysmex XN 9000
Reference Range
Component | Age | Sex | Low | High | Units |
Reticulocyte Count | All | All | 0.5 | 2.5 | % |
Reticulocyte Hemoglobin | ≥18 years | All | 31.2 | 39.9 | pg |
*Reticulocyte Hemoglobin | <18 years | All | N/A | N/A | N/A |
Immature Reticulocyte Fraction | ≥18 years | Female | 3.0 | 15.9 | % |
Immature Reticulocyte Fraction | ≥18 years | Male | 2.3 | 13.4 | % |
*Immature Reticulocyte Fraction | <18 years | All | N/A | N/A | N/A |
.*No reference range currently available for patients under 18.
Section
Hematology
Performing Location
University of Vermont Medical Center
Is the UVMMC lab NY State Certified to perform this testing? Yes/No