Test Code LAB2518 BACTERIAL CULTURE, SOLID OBJECT
Additional Codes
Orderable Codes:
Epic Code | Atlas Code | Mayo Access ID | Order LOINC |
LAB2518 | SORC | N/A | 6463-4 |
Specimen Information
Container | Specimen | Temperature | Collect/Submit | Stability |
Sterile Container | Varies | Refrigerate | * | 24 hours |
Intravascular catheter tips (A-line, groshong, etc)
*Distal 5 cm should be aseptically removed and submitted in a urine container. Explanted hardware is acceptable, but infected tissue surrounding foreign material is preferred. Foley catheter tips are not suitable for culture.
Test Schedule / Analytical Time / Test Priority
Daily / Catheter tips 48 hours, orthopedic hardware, etc. 5 days / Not available STAT
Method
Culture
Instrumentation
Manual Method
Reference Range
Negative: No growth. Less than 15 colonies on the blood agar plate suggest that the bacteria are not causing catheter related sepsis. Isolates are identified by gram morphology only. Final results are available in 2 days.
Positive: More than 15 colonies on the blood agar plate correlates best with catheter-associated sepsis. Results are usually available in 2 days. (Three or more organisms may be reported as “Mixed organisms”).
Section
Microbiology-1
Performing Location
University of Vermont Medical Center
Is the UVMMC lab NY State Certified to perform this testing? Yes/No
Yes
CPT Code(s)
Description | CPT Code |
Bacterial Culture, Solid Object | 87070 |